CARDIOPRO is a specialised Physiological monitoring and biofeedback application for the cardiovascular and respiratory systems. It can perform real-time feedback on respiratory sinus arrhythmia (RSA) and heart rate variability (HRV) from an electrocardiography (EKG) or blood volume pulse (BVP) sensor. The system can also monitor other key physiological functions, such as respiration, temperature and skin conductance, for the most complete view on your client's physiology. With a simple graphic user interface and comprehensive reporting features, CardioPro lets you easily flow through the steps of recording, reviewing, and analyzing data. CardioPro is powerful enough for research applications, yet remains flexible for clinical work.


CARDIOPRO 2.0 NEW FEATURES:

1 or 5-minute time window for 2D and 3D spectrum display:
An option to select a one-minute sliding time window provides CardioPro with a much faster and more significant reactions to physiological change. Heart rate variability (HRV) feedback with the 2D or 3D spectrum graphs is now much more responsive!



Raw and IBI data export function:
With CardioPro 2.0, researchers can export all the data generated within the system with just a few clicks of the mouse! Whether you want to get access to the raw sensor data or the table of inter-beat intervals (IBI), CardioPro can easily convert its data format to standard comma-separated text files.



Option to record and monitor skin conductance:
A new sensor type was added to the list of physiological modalities that can be monitored with CardioPro. Users can now record skin conductance (SC), along with temperature, blood volume pulse (BVP), respiration and electrocardiography (EKG).



Bar graphs for real-time feedback on the power of the low and high frequency (LF and HF) components of HRV:
Where the 2D and 3D FFT spectrum graphs show the overall power for each frequency component, CardioPro 2.0 offers a quick way to get a reading on the difference in power between LF and HF. Two bar graphs were added to the RSA display to show these values in normalized units.

Ability to use CardioPro with a blood volume pulse (BVP) sensor:
Cardiopro is now able to compute HRV from an easy-to-use BVP sensor, which is strapped around the person's fingertip. This makes client preparation a snap!

Download
CardioPro Manual (1,773KB)
System Requirements (88KB)

   